| Source characteristics | Superbend (5.0 T, single pole) |
| Energy range | 5-17 keV |
| Monochromator | Double-crystal Si(111) |
| Measured Flux (1.9 GeV, 500 mA) | 3.5×1011 ph/s at 12keV through 0.1mm pinhole |
| Resolving power (E/ΔE) | 7000 |
| Divergence (max at sample) | 3.0 (h) x 0.31 (v) mrad |
| Spot size | 15x15um to 200x200um user-adjustable apertured beam |
| Endstation | Mini-hutch |
| Detector | Pilatus3 2M |
| Automounter | Rigaku ACTOR; robot dewar holds 5 ALS-style, Unipucks or Rigaku ACTOR pucks |
| Sample format | Hampton or Mitegen ALS pins |
| Kappa | Not available |
| Special notes | Computers for data processing and analysis available Full remote operation capability User-adjustable aperture (CVC) installed |
| Local contact | Jay Nix |
| Beamline phone | 510-495-2082 |
| def.site file | def.site |